Case Study

Cheese Manufacturer Slashes Mold Inhibitor Use in Half

Case Study

Cheese Manufacturer Slashes Mold Inhibitor Use in Half

Saves $143,000 annually with an AutoJet® food safety spray system

Problem:
A cheese manufacturer needed a better way to apply a costly mold inhibitor – natamycin – on blocks of cheese on a moving conveyor. The natamycin was applied to the cheese as it passed through a spray station but the manufacturer was struggling to apply the proper volume. Over-application was wasteful; under-application resulted in increased mold counts. In addition, the nozzles sprayed continuously – even between the blocks of cheese, adding to the waste issue.

Spraying on cheese application drawing

Solution:
Spraying Systems Co. solved the problem with an AutoJet Food Safety Spray System for Cheese. A single system now applies the natamycin to cheese on two lines. Each line has four hydraulic PulsaJet® electrically-actuated spray nozzles, strategically placed to apply the natamycin uniformly on all sides of the cheese without waste. Precision Spray Control (PSC) is used to ensure the proper volume of natamycin is applied – even when operating conditions such as line speed changes. The spray controller makes automatic adjustments to the flow rate, eliminating over- and under-application problems. Object sensors are used to detect when cheese blocks are in the spray station. The nozzles are triggered to spray only when the cheese blocks are in the proper position.

Results:
Use of the AutoJet Food Safety Spray System has reduced natamycin consumption by nearly 50% – a savings of US$143,000 per year. The cost of the system was offset in less than five months. In addition to the ongoing cost savings, the manufacturer is no longer plagued by unacceptable mold counts.

For complete details of this case study click here to see the PDF version.

AutoJet 1550+ Controller

AutoJet Model 1550+ Modular Spray System

Provides complete automated spray control of nozzles to ensure precise and accurate placement of the natamycin with minimal waste

Precision Spray Control Savings

Kiểm soát phun chính xác (PSC)

PSC bao gồm việc bật và tắt vòi phun rất nhanh để kiểm soát lưu lượng. Chu trình này diễn ra nhanh đến mức lưu lượng thường có vẻ không đổi. Áp suất được duy trì không đổi, cho phép lưu lượng thay đổi mà không làm thay đổi hiệu suất phun.

PulsaJet Nozzle

PulsaJet Nozzles

Provide high transfer efficiency to minimize waste and messy overspray

Liên hệ với chúng tôi để tìm giải pháp phù hợp cho ứng dụng của bạn. Nói chuyện với chuyên gia