Crude Distillation Unit

Crude Distillation Unit

Nullam in ipsum ex.
Duis dolor nisi, iaculis eu odio a, volutpat semper odio. Nullam convallis purus at leo dapibus, quis congue justo eleifend. Pellentesque sit amet sollicitudin felis.
CDU Water Wash

1. Water Wash

Problem: Understanding how to effectively inject wash water in most efficient placement to dilute acid that has formed in the liquid phase and dissolve salt deposits.

Best practice: Invest in a CFD study to validate performance before beginning injector design. Using flow rate and pressure drop to determine injection points is not enough. Using quills instead of spray injectors will likely create excess free water that will not properly interact with the vapor stream and may cause erosion and other corrosion issues. 

CDU Filming Corrosion Inhibitor

2. Filming Corrosion Inhibitor

Problem: Provide a protective barrier, a film, on the inside of the overhead line

Best practice: WhirlJet® Hollow Cone spray nozzles are available in low flow capacity sizes and can be operated at lower pressures to maximize drop size and filming effectiveness. The hollow cone spray pattern directs the filmer to the pipe wall.

CDU Neutralizing Amine

3. Neutralizing Amine

Problem: Injection system that is ineffective that can lead to wasted chemical and possible corrosion on overhead piping due to neutralizer that is not volatilized

Best practice: Using a spray injector designed specifically for atomization with steam is the optimal solution – Steam Atomized Retractable Injector. This solution is preferable to feeding the neutralizer through a quill along with steam. Use of the Steam Atomized Retractable Injector ensures none of the neutralizer remains in a liquid state and is then more effective at neutralizing the HCl. 

CDU Fin Fan Water Wash

4. Fin Fan Water Wash

Problem: Poor wash water distribution and pooling on the floor of the header box

Best practice: Position the spray nozzles inside the header box itself or by using the clean-out plugs, if available, to install individual spray nozzles at pre-determined locations. Invest in a CFD study to validate performance before beginning injector design. The process gas flow rate and velocity greatly affect the performance of the spray injector, and CFD can assist in optimal spray nozzle placement.

CDU Overhead Water Wash

5. Overhead Water Wash

Problem: Poor wash water distribution and pooling on the floor of the header box

Best practice: Position the spray nozzles inside the header box itself or by using the clean-out plugs, if available, to install individual spray nozzles at pre-determined locations. Invest in a CFD study to validate performance before beginning injector design. The process gas flow rate and velocity greatly affect the performance of the spray injector, and CFD can assist in optimal spray nozzle placement.

CDU VGO Wash bed spray header

6. VGO Wash Bed Spray Header

Problem: Maintain wet zones in the wash bed – dry zones can form coke and lead to higher pressure drops in the column

Best practice: Maximum Free Passage (MFP) FullJet® Full Cone spray nozzles reduce the chance to plug the spray nozzles, so nozzles run longer, as well as provide excellent coverage and larger droplet sizes at lower pressures.