top banner
top banner
B41 - FullJet® Spray Nozzles, Vaneless Spray
Performance Data
GANV, GGANV
*At the stated pressure in bar.
Inlet
Conn.
(in.)
Capacity
Size
Orifice
Dia.
Nom.
(mm)
Max.
Free
Passage
Dia.
(mm)
Capacity
(liters per minute)*
Spray
Angle
(°)*
0.4 0.5 0.7 1 1.5 2 3 4 6 7 0.5 1.5 6
1/4 5 2.8 2.0 1.4 1.6 1.9 2.3 2.8 3.2 3.9 4.6 5.6 6.0 68 75 82
7 3.2 2.4 2.0 2.3 2.7 3.2 3.9 4.5 5.5 6.4 7.8 8.4 68 75 82
8 4.0 2.8 2.3 2.6 3.1 3.6 4.5 5.2 6.3 7.3 8.9 9.6 75 80 85
10 4.0 3.2 2.9 3.2 3.8 4.6 5.6 6.4 7.9 9.1 11.2 12.1 75 80 85
11 4.0 3.6 3.2 3.5 4.2 5.0 6.1 7.1 8.7 10.0 12.3 13.3 75 80 85
3/8 11 4.4 3.2 3.2 3.5 4.2 5.0 6.1 7.1 8.7 10.0 12.3 13.3 75 85 83
13 4.4 3.6 3.7 4.2 5.0 5.9 7.3 8.4 10.3 11.9 14.5 15.7 75 85 83
16 4.4 4.0 4.6 5.2 6.1 7.3 8.9 10.3 12.6 14.6 17.9 19.3 75 85 83
20 5.6 4.4 5.8 6.4 7.6 9.1 11.2 12.9 15.8 18.2 22 24 75 85 83
23 5.6 4.8 6.6 7.4 8.8 10.5 12.8 14.8 18.2 21 26 28 75 85 83
26 6.0 5.2 7.5 8.4 9.9 11.9 14.5 16.8 21 24 29 31 75 85 83
29 6.0 5.6 8.4 9.3 11.1 13.2 16.2 18.7 23 26 32 35 75 85 83
33 7.5 6.0 9.5 10.6 12.6 15.0 18.4 21 26 30 37 40 75 85 83
1/2 32 7.9 5.2 9.2 10.3 12.2 14.6 17.9 21 25 29 36 39 85 90 95
40 7.9 6.0 11.5 12.9 15.3 18.2 22 26 32 36 45 48 85 90 95
48 7.9 7.1 13.8 15.5 18.3 22 27 31 38 44 54 58 85 90 95
56 9.9 7.5 16.1 18.1 21 26 31 36 44 51 63 68 85 90 95
64 9.9 8.3 18.5 21 24 29 36 41 51 58 71 77 85 90 95
72 9.9 9.1 21 23 27 33 40 46 57 66 80 87 85 90 95
Dimensions and Weights
Angle
Type
Nozzle
Type
Inlet
Conn.
(in.)
A
(mm)
B
(mm)
C
(mm sq.)
D
(mm)
L
(mm)
Net
Weight
(kg)
images/full_GANV_dwg_sm_fmt1.jpg GANV
(F)
1/4 14.5 22.5 19 24 32 .08
3/8 17.5 25 22 28.5 36 .11
1/2 19.5 33.5 25.5 32.5 46 .16
images/full_GGANV_dwg_sm_fmt1.jpg GGANV
(M)
1/4 14.5 22.5 19 24 32 .07
3/8 17.5 25 22 28.5 36 .10
1/2 19.5 35 25.5 32.5 48 .15
Materials
Material Material
Code
Nozzle Type
GANV GGANV
Brass (none)
303 Stainless Steel SS
Ordering Info
Standard Spray Nozzle
1/4 GANV SS 10
| | | |
Inlet
Conn.
Nozzle
Type
Material
Code
Capacity
Size

BSPT connections require the addition of a “B” prior to the inlet connection.