- Accessories
- Air line filters
- Air pressure regulators
- Liquid pressure regulators
- Pressure gauges
- Solenoid valves
- Strainers
- For 1/4JH siphon air atomizing nozzles, request Data Sheet 10188
- For 1/4JT pressure-fed air atomizing nozzles, request Data Sheet 2843
- For 45400 humidification unit, request Data Sheet 45400
- For YMF MiniFogger® II, request Data Sheet YMF
| Set-up No. |
Orifice Diameter (mm) |
Data per Nozzle (Air Pressure 0.3 MPa) | |||
| Liquid Capacity l/h |
Air Capacity l/min |
Mean Droplet Size (micron)* |
Spray Distance (m) |
||
| E-1 | 0.5 | 2.2 | 39 | 8.6 | 4 |
|
*Sauter Mean Diameter 0.1 MPa = 1 bar |
|||||
| Atomizing Air |
Water Capacity |
|
| Air Press. bar |
Air Capacity l/min |
l/h |
| .7 | 10.7 | 1.2 |
| 1.4 | 16.1 | 1.6 |
| 2 | 20.9 | 2.0 |
| 2.8 | 25.9 | 2.3 |
| 3.5 | 31.0 | 2.7 |
| 4 | 36.7 | 3.0 |
| Pressure bar |
Liquid Capacity l/h |
| 35 | 3.6 |
| 41 | 3.8 |
| 48 | 4.2 |
| 55 | 4.5 |
| 62 | 4.7 |
| 69 | 4.9 |
| Material | Material Code |
Nozzle Type | ||||
| JH | JT | 45400 | YMF | 46215 | ||
| Nozzle Bodies | ||||||
| Brass | (none) | • | ||||
| Nickel-plated Brass | (none) | • | • | |||
| Kynar® | KY | • | ||||
| 303 Stainless Steel | SS | • | • | |||
| Air/Fluid Caps | ||||||
| Nickel-plated Brass | SSBR | • | • | |||
|
Nickel-plated Brass Air Cap and 303 Stainless Steel Fluid Cap |
SSBR | • | • | |||
| Kynar | KY | • | ||||
| 303 Stainless Steel | SS | • | • | • | ||
| Complete Nozzle Assembly | |||||||
| Nozzle Body* | Spray Set-up | ||||||
| 1/4 | JH | – | SS | + | SU1A | – | SS |
| | | | | | | | | | | |||
| Inlet Conn. |
Nozzle Body |
Material Code |
Spray Set-up No. |
Material Code |
|||
|
*Includes retainer and gasket. |
|||||||
BSPT connections require the addition of a “B” prior to the nozzle body inlet connection.
To order spray set-up only, use spray set-up number and material code: SU1A-SS.
To order fluid cap only, use fluid cap number (shown in performance data charts) and material code: 1650-SS.
To order air cap only, use air cap number (shown in performance data charts) and material code: 64-SS.
To order spray nozzle without set-up, use inlet connection, nozzle body and material code: 1/4JH-SS.
| Humidification Unit | ||
| YMF-2 | – | 2 |
| | | | | |
| Humidification Unit Type |
No. of Set-ups |
|
| Humidification Unit | ||
| 45400 | – | 1 |
| | | | | |
| Humidification Unit Type |
No. of Set-ups |
|
A – Float box with float valve
B – TW liquid strainer
C – Air atomizing nozzle
D – Spray pipe assembly
E – Pipe hanger
F – Air filter
G – Pressure regulator with gauge
H – Solenoid valve
I – Switching relay
J – Humidistat