top banner
top banner
F47 - Pressure Spray Set-ups, External Mix, 1/2J Series
Features and Benefits
  • The dimensions “A”, “B” and “C” are the pattern widths at distances from the nozzle.
  • The total distance of spray projection from the nozzle to the maximum dispersal point is represented by “D”.
  • SUE75 and SU380C are pressure set-ups using pressurized liquids.
  • In SU380C, the air and liquid mix internally, while in SUE75, they mix externally.
  • SU70 is a siphon set-up with the air and siphoned liquid mixing externally.
Air Caps
images/air_Caps_Flat_fmt1.jpg

Flat spray air caps produce a flat spray pattern.

images/air_flat_s_pttrn_1_2J__fmt1.jpg

1705 retainer ring and 8491 gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer.

Performance Data
Flat Spray (External Mix)
*At the stated pressure in bar.
Spray
Set-up
No.
Spray
Set-up
Consists of
Fluid and
Air Cap
Combination
Liquid Capacity (liters per hour)* and Air Capacity (liters per minute)*
Liquid Pressure
0.2 0.35 0.5 0.7 1
Air Press. l/h Air
l/min
Air Press. l/h Air
l/min
Air Press. l/h Air
l/min
Air Press. l/h Air
l/min
Air Press. l/h Air
l/min
SUE75 Fluid Cap
250375
+
Air Cap
14356
2.1 522 877 2.8 681 1075 3.15 795 1174 3.85 953 1358 5.6 1158 1839
2.45 522 962 3.15 681 1174 3.5 795 1273 4.2 953 1457 6.0 1158 1952
2.8 522 1075 3.5 681 1273 3.85 795 1358 4.9 953 1641 6.3 1158 2037
3.15 522 1174 3.85 681 1358 4.2 795 1457 5.25 953 1754 6.6 1158 2122
4.2 681 1457 4.55 795 1556 5.6 953 1839 7.0 1158 2207
4.9 795 1641 6.0 953 1952
Spray
Set-up
No.
Spray
Dimensions
Air* Liquid* A
(cm)
B
(cm)
C
(cm)
D
(m)
SUE75 2.45
3.5
3.85
4.9
6.3
.20
.35
.50
.70
1.0
21.6
22.9
24.1
24.1
25.4
36.8
42
44.5
46
48
52
55
58
61
66
5.8
6.7
7.0
7.6
8.9