top banner
top banner
B46 - Quick FullJet® Spray Nozzles, Square Spray
Performance Data
*At the stated pressure in bar.
Body
Inlet
Conn.
(in.)
Quick
FullJet
Tip Type
Capacity
Size
Orifice
Dia.
Nom.
(mm)
Max.
Free
Passage
Dia.
(mm)
Capacity
(liters per minute)*
Spray
Angle
(°)*
QHA-SQ QLHA-SQ 0.4 0.5 0.7 1.5 2 3 4 6 7 10 0.5 1.5 6
1/8, 1/4,
3/8, 1/2
3.6SQ 1.6 1.3 1.1 1.2 1.4 1.9 2.2 2.7 3.1 3.7 4.0 4.7 40 52 47
6SQ 2.4 1.3 1.8 2.0 2.3 3.2 3.7 4.5 5.1 6.1 6.6 7.8 60 66 60
1/4, 3/8, 1/2 10SQ 2.8 1.6 2.9 3.3 3.8 5.4 6.2 7.4 8.5 10.2 11.0 13.0 62 67 61
12SQ 3.2 1.6 3.5 3.9 4.6 6.5 7.4 8.9 10.2 12.3 13.2 15.5 70 75 68
14.5SQ 3.9 1.6 4.3 4.7 5.5 7.8 9.0 10.8 12.3 14.8 15.9 18.8 78 82 75
3/8, 1/2 18SQ 4.0 2.4 5.3 5.9 6.9 9.7 11.1 13.4 15.3 18.4 19.8 23 71 75 68
1/2 36SQ 6.4 3.2 10.6 11.8 13.7 19.5 22 27 31 37 40 47 78 82 75
Dimensions and Weights
Standard Nozzle
Type
Length
(mm)
Hex.
(mm)
Net
Weight
(kg)
images/full_QHA-SQ_QLHA-SQ_dw_fmt1.jpg QJA+QHA-SQ 50 25.4 .10
QJJA+QHA-SQ 47 25.4 .10
QJLA+QLHA-SQ 57 28.6 .14
QJJLA+QLHA-SQ 58 28.6 .13
Body Types
Inlet
Conn.
(in.)
Standard Body
Conn. F Conn. M
QJA QJLA QJJA QJJLA
1/8
1/4
3/8
1/2
Materials
Material Material
Code
Spray Tip
QHA-SQ QLHA-SQ
Brass (none)
303 Stainless Steel SS
Ordering Info
Quick FullJet Complete Nozzle
Nozzle Body Spray Tip
3/8 QJA SS + QHA SS 12SQ
| | | | | |
Inlet
Conn.
Body
Type
Material
Code
Tip
Type
Material
Code
Capacity
Size

BSPT connections require the addition of a “B” prior to the nozzle body inlet connection.