top banner
top banner
F22 - Pressure Spray Set-ups, External Mix, High Transfer Efficiency (HTE), 1/4J Series
Performance Data
Round Spray (External Mix)
*At the stated pressure in psi.
Spray
Set-up
No.
Spray
Set-up
Consists of
Fluid and
Air Cap
Combination
Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)*
Liquid Pressure
5 10 15 20 30
Air Press. gph scfm Air Press. gph scfm Air Press. gph scfm Air Press. gph scfm Air Press. gph scfm
SU-HTE91A Fluid Cap
PF2850
+
Air Cap
LP60650-60
4.0 3.0 1.9
6.0 3.0 2.5 6.0 4.2 2.5
8.0 3.0 2.9 8.0 4.2 2.9 8.0 5.1 2.9 8.0 6.0 2.9 8.0 7.2 2.9
10.0 3.0 3.4 10.0 4.2 3.4 10.0 5.1 3.4 10.0 6.0 3.4 10.0 7.2 3.4
12.0 3.0 3.8 12.0 4.2 3.8 12.0 5.1 3.8 12.0 6.0 3.8 12.0 7.2 3.8
14.0 3.0 4.1 14.0 4.2 4.1 14.0 5.1 4.1 14.0 6.0 4.1 14.0 7.2 4.1
16.0 3.0 4.5 16.0 4.2 4.5 16.0 5.1 4.5 16.0 6.0 4.5 16.0 7.2 4.5
SU-HTE91B Fluid Cap
PF2050
+
Air Cap
LP60650-60
4.0 1.6 1.9
6.0 1.6 2.5
8.0 1.6 2.9 8.0 2.2 2.9
10.0 1.6 3.4 10.0 2.2 3.4 10.0 2.6 3.4 10.0 3.1 3.4
12.0 1.6 3.8 12.0 2.2 3.8 12.0 2.6 3.8 12.0 3.1 3.8
14.0 1.6 4.1 14.0 2.2 4.1 14.0 2.6 4.1 14.0 3.1 4.1 14.0 3.7 4.1
16.0 1.6 4.5 16.0 2.2 4.5 16.0 2.6 4.5 16.0 3.1 4.5 16.0 3.7 4.5
SU-HTE91C Fluid Cap
PF1650
+
Air Cap
LP60650-60
6.0 1.0 2.5
8.0 1.0 2.9 8.0 1.4 2.9
10.0 1.0 3.4 10.0 1.4 3.4
12.0 1.0 3.8 12.0 1.4 3.8
14.0 1.0 4.1 14.0 1.4 4.1 14.0 1.7 4.1 14.0 2.0 4.1
16.0 1.0 4.5 16.0 1.4 4.5 16.0 1.7 4.5 16.0 2.0 4.5

Add DF to part number for “Drip Free™” set-ups. Example: SU-HTE60D-DF.

The operating pressures and flow rates are based on spraying water and air at room temperature.

Adjustments may need to be made to accommodate other liquids with different characteristics.

Spray
Set-up
No.
Spray
Dimensions
Air* Liquid* A
(in.)
B
(in.)
C
(in.)
D
(in.)
SU-HTE91A 3
5
10
15
5
10
15
5
5
5
5
10
10
10
1
3-1/2
2
2
2-1/2
1-1/2
1
3
3-1/2
3-1/2
3-1/2
4-1/2
2-1/2
2-1/2
3-1/2
5
4
5
5-1/2
3-1/2
4
44
40
43
44
39
41
47
SU-HTE91B 3
5
10
15
5
10
15
5
5
5
5
10
10
10
2
2-1/2
2
2
2-1/2
2
2
3-1/2
3
3-1/2
3
3
3-1/2
3
4-1/2
3-1/2
5
5
3-1/2
5
5
41
42
42
49
42
42
49
SU-HTE91C 5
10
15
5
10
15
5
5
5
10
10
10
3-1/2
4
4
2
3
3
4
4-1/2
5
4
4
3-1/2
5
5-1/2
6
4-1/2
4-1/2
5
34
38
46
35
38
52
Ordering Info
Spray Set-up Only
Spray Set-up
HTE60D SS
| |
Spray
Set-up Number
Material
Code
Complete Nozzle Assembly
Nozzle Body* Spray Set-up
1/4 J SS + SU-HTE60D SS
| | | | |
Inlet
Conn.
Nozzle
No.
Material
Code
Spray
Set-up Number
Material
Code

BSPT connections require the addition of a “B” prior to the nozzle body inlet connection.

*To order fluid cap only, use fluid cap number (shown in performance data charts and material code).

To order air cap only, use air cap number (shown in performance data charts and material code).

To order spray nozzle without set-up, use inlet connection, nozzle body and material code.

To order Drip Free set-ups, add DF after set-up number: SU-HTE60D-DF – SS.