Performance Data
Flat Spray (External Mix)
*At the stated pressure in psi.
Spray
Set-up
No.
Spray
Set-up
Consists of
Fluid and
Air Cap
Combination
Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)*
Liquid Pressure
5 10 15 20 30
Air Press. gph scfm Air Press. gph scfm Air Press. gph scfm Air Press. gph scfm Air Press. gph scfm
SU-HTE62F Fluid Cap
PF16100
+
Air Cap
LP120262-90
4.0 1.0 2.0
6.0 1.0 2.5 6.0 1.4 2.5
8.0 1.0 2.9 8.0 1.4 2.9 8.0 1.7 2.9 8.0 2.0 2.9
10.0 1.0 3.3 10.0 1.4 3.3 10.0 1.7 3.3 10.0 2.0 3.3 10.0 2.4 3.3
12.0 1.0 3.6 12.0 1.4 3.6 12.0 1.7 3.6 12.0 2.0 3.6 12.0 2.4 3.6
14.0 1.0 4.0 14.0 1.4 4.0 14.0 1.7 4.0 14.0 2.0 4.0 14.0 2.4 4.0
16.0 1.0 4.3 16.0 1.4 4.3 16.0 1.7 4.3 16.0 2.0 4.3 16.0 2.4 4.3
SU-HTE64C Fluid Cap
PF35100
+
Air Cap
LP1302100-60
6.0 4.7 4.0
8.0 4.7 4.7 8.0 6.6 4.7
10.0 4.7 5.3 10.0 6.6 5.3
12.0 4.7 5.9 12.0 6.6 5.9 12.0 8.1 5.9
14.0 4.7 6.5 14.0 6.6 6.5 14.0 8.1 6.5 14.0 9.4 6.5 14.0 11.4 6.5
16.0 4.7 7.1 16.0 6.6 7.1 16.0 8.1 7.1 16.0 9.4 7.1 16.0 11.4 7.1
SU-HTE64D Fluid Cap
PF28100
+
Air Cap
LP1302100-60
6.0 3.0 4.0
8.0 3.0 4.7 8.0 4.2 4.7
10.0 3.0 5.3 10.0 4.2 5.3 10.0 5.1 5.3
12.0 3.0 5.9 12.0 4.2 5.9 12.0 5.1 5.9
14.0 3.0 6.5 14.0 4.2 6.5 14.0 5.1 6.5 14.0 6.0 6.5 14.0 7.2 6.5
16.0 3.0 7.1 16.0 4.2 7.1 16.0 5.1 7.1 16.0 6.0 7.1 16.0 7.2 7.1
SU-HTE64E Fluid Cap
PF20100
+
Air Cap
LP1302100-60
4.0 1.6 3.2
6.0 1.6 4.0
8.0 1.6 4.7 8.0 2.2 4.7 8.0 2.6 4.7
10.0 1.6 5.3 10.0 2.2 5.3 10.0 2.6 5.3 10.0 3.1 5.3 10.0 3.7 5.3
12.0 1.6 5.9 12.0 2.2 5.9 12.0 2.6 5.9 12.0 3.1 5.9 12.0 3.7 5.9
14.0 1.6 6.5 14.0 2.2 6.5 14.0 2.6 6.5 14.0 3.1 6.5 14.0 3.7 6.5
16.0 1.6 7.1 16.0 2.2 7.1 16.0 2.6 7.1 16.0 3.1 7.1 16.0 3.7 7.1
SU-HTE64F Fluid Cap
PF16100
+
Air Cap
LP1302100-60
4.0 1.0 3.2
6.0 1.0 4.0 6.0 1.4 4.0
8.0 1.0 4.7 8.0 1.4 4.7 8.0 1.7 4.7 8.0 2.0 4.7
10.0 1.0 5.3 10.0 1.4 5.3 10.0 1.7 5.3 10.0 2.0 5.3 10.0 2.4 5.3
12.0 1.0 5.9 12.0 1.4 5.9 12.0 1.7 5.9 12.0 2.0 5.9 12.0 2.4 5.9
14.0 1.0 6.5 14.0 1.4 6.5 14.0 1.7 6.5 14.0 2.0 6.5 14.0 2.4 6.5
16.0 1.0 7.1 16.0 1.4 7.1 16.0 1.7 7.1 16.0 2.0 7.1 16.0 2.4 7.1

Add DF to part number for “Drip Free™” set-ups. Example: SU-HTE60D-DF.

The operating pressures and flow rates are based on spraying water and air at room temperature.

Adjustments may need to be made to accommodate other liquids with different characteristics.

Spray
Set-up
No.
Spray
Dimensions
Air* Liquid* A
(in.)
B
(in.)
C
(in.)
D
(in.)
SU-HTE62F 3
5
10
15
5
10
15
5
5
5
5
10
10
10
9
8-1/2
6
6-1/2
9
8
7-1/2
11
9-1/2
7-1/2
7-1/2
11
9
9
12-1/2
10-1/2
8-1/2
9
12-1/2
12
11
26
28
24
25
26
26
26
SU-HTE64C 5
10
15
5
10
15
5
5
5
10
10
10
12
11
6
14
12
8
16
11-1/2
9
16
16
12
19
15
10
19
18
13
30
34
44
29
35
41
SU-HTE64D 5
10
15
5
10
15
5
5
5
10
10
10
11
8
7
11
8
7
13
10
8
12
11
8
14
13
11
18
14
13
39
40
50
30
41
53
SU-HTE64E 3
5
10
15
5
10
15
5
5
5
5
10
10
10
7
6-1/2
5
5
7-1/2
5-1/2
5-1/2
9
6-1/2
5
5
8-1/2
6-1/2
6-1/2
11
8-1/2
6
5-1/2
9
7-1/2
7
23
25
33
39
29
35
43
SU-HTE64F 3
5
10
15
5
10
15
5
5
5
5
10
10
10
9
7
6-1/2
5-1/2
9
7-1/2
5-1/2
11
9
8
7
11
9
7
13-1/2
11-1/2
10
8-1/2
13-1/2
10
8-1/2
27
27
30
30
28
29
29