F19 - Pressure Spray Set-ups, External Mix, High Transfer
Efficiency (HTE), 1/4J Series
Features and Benefits
- A new air cap design enables the use of lower air pressures to achieve the same spray performance as conventional external mix set-ups.
- HTE set-ups operate at pressures as low as 5 psi (0.3 bar).
- A large air chamber directly feeds the air exit orifices. Design provides high liquid transfer efficiency, minimal air loss, and minimal misting.
- Air consumption is reduced and maximum spray coverage on the target is achieved.
- For complete information, request HTE Air Atomizing Set-ups Bulletin.
- See also
- Section G, Automatic Spray Nozzles
Air Caps
HTE air cap produces a flat spray and a round spray.
1158 retainer ring and 3612 gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer.
Performance Data
Flat Spray (External Mix)
| *At the stated pressure in psi. | ||||||||||||||||
|
Spray Set-up No. |
Spray Set-up Consists of Fluid and Air Cap Combination |
Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)* | ||||||||||||||
| Liquid Pressure | ||||||||||||||||
| 5 | 10 | 15 | 20 | 30 | ||||||||||||
| Air Press. | gph | scfm | Air Press. | gph | scfm | Air Press. | gph | scfm | Air Press. | gph | scfm | Air Press. | gph | scfm | ||
| SU-HTE60D | Fluid
Cap PF28100 + Air Cap LP130262-60 |
8.0 | 3.0 | 3.3 | 8.0 | 4.2 | 3.3 | – | – | – | – | – | – | – | – | – |
| 10.0 | 3.0 | 3.8 | 10.0 | 4.2 | 3.8 | 10.0 | 5.1 | 3.8 | – | – | – | – | – | – | ||
| 12.0 | 3.0 | 4.2 | 12.0 | 4.2 | 4.2 | 12.0 | 5.1 | 4.2 | 12.0 | 6.0 | 4.2 | – | – | – | ||
| 14.0 | 3.0 | 4.5 | 14.0 | 4.2 | 4.5 | 14.0 | 5.1 | 4.5 | 14.0 | 6.0 | 4.5 | 14.0 | 7.2 | 4.5 | ||
| 16.0 | 3.0 | 4.9 | 16.0 | 4.2 | 4.9 | 16.0 | 5.1 | 4.9 | 16.0 | 6.0 | 4.9 | 16.0 | 7.2 | 4.9 | ||
| SU-HTE60E | Fluid
Cap PF20100 + Air Cap LP130262-60 |
6.0 | 1.6 | 2.8 | 6.0 | 2.2 | 2.8 | – | – | – | – | – | – | – | – | – |
| 8.0 | 1.6 | 3.3 | 8.0 | 2.2 | 3.3 | 8.0 | 2.6 | 3.3 | – | – | – | – | – | – | ||
| 10.0 | 1.6 | 3.8 | 10.0 | 2.2 | 3.8 | 10.0 | 2.6 | 3.8 | 10.0 | 3.1 | 3.8 | – | – | – | ||
| 12.0 | 1.6 | 4.2 | 12.0 | 2.2 | 4.2 | 12.0 | 2.6 | 4.2 | 12.0 | 3.1 | 4.2 | – | – | – | ||
| 14.0 | 1.6 | 4.5 | 14.0 | 2.2 | 4.5 | 14.0 | 2.6 | 4.5 | 14.0 | 3.1 | 4.5 | 14.0 | 3.7 | 4.5 | ||
| 16.0 | 1.6 | 4.9 | 16.0 | 2.2 | 4.9 | 16.0 | 2.6 | 4.9 | 16.0 | 3.1 | 4.9 | 16.0 | 3.7 | 4.9 | ||
| SU-HTE60F | Fluid
Cap PF16100 + Air Cap LP130262-60 |
4.0 | 1.0 | 2.3 | – | – | – | – | – | – | – | – | – | – | – | – |
| 6.0 | 1.0 | 2.8 | – | – | – | – | – | – | – | – | – | – | – | – | ||
| 8.0 | 1.0 | 3.3 | 8.0 | 1.4 | 3.3 | 8.0 | 1.7 | 3.3 | 8.0 | 2.0 | 3.3 | – | – | – | ||
| 10.0 | 1.0 | 3.8 | 10.0 | 1.4 | 3.8 | 10.0 | 1.7 | 3.8 | 10.0 | 2.0 | 3.8 | – | – | – | ||
| 12.0 | 1.0 | 4.2 | 12.0 | 1.4 | 4.2 | 12.0 | 1.7 | 4.2 | 12.0 | 2.0 | 4.2 | 12.0 | 2.4 | 4.2 | ||
| 14.0 | 1.0 | 4.5 | 14.0 | 1.4 | 4.5 | 14.0 | 1.7 | 4.5 | 14.0 | 2.0 | 4.5 | 14.0 | 2.4 | 4.5 | ||
| 16.0 | 1.0 | 4.9 | 16.0 | 1.4 | 4.9 | 16.0 | 1.7 | 4.9 | 16.0 | 2.0 | 4.9 | 16.0 | 2.4 | 4.9 | ||
Add DF to part number for “Drip Free™” set-ups. Example: SU-HTE60D-DF.
The operating pressures and flow rates are based on spraying water and air at room temperature.
Adjustments may need to be made to accommodate other liquids with different characteristics.
|
Spray Set-up No. |
Spray Dimensions |
|||||
| Air* | Liquid* | A (in.) |
B (in.) |
C (in.) |
D (in.) |
|
| SU-HTE60D | 10 15 10 15 10 |
5 5 10 10 20 |
7 5 11-1/2 6 10 |
13 6 13-1/2 9 15 |
14 8 13 10 11 |
36 40 40 45 41 |
| SU-HTE60E | 5 10 15 5 10 15 |
5 5 5 10 10 10 |
7 4 3 8 8 6-1/2 |
9 4-1/2 4-1/2 11 9 7 |
11 4-1/2 5-1/2 13 9 7-1/2 |
25 31 34 22 27 32 |
| SU-HTE60F | 3 5 10 15 5 10 15 |
5 5 5 5 10 10 10 |
9-1/2 9 8 6-1/2 8-1/2 7-1/2 6 |
11 10 9 7-1/2 9-1/2 9 7-1/2 |
13 12 11-1/2 8-1/2 12 11 9-1/2 |
23 24 25 28 22 25 29 |